Technical description
Inground luminaire, walk-over, suitable for outdoor and underwater environments up to 10 m (IP66/IP68), with operating temperature range: -20°C / +50°C. The light source consists of a single 3W power Led chip powered at 24V constant voltage with integrated driver. The various angles of grazing emission make it ideal for marking pedestrian paths or illuminating. The source is set back for greater visual comfort. Color rendering index CRI > 90. Oceano is equipped with IdroSkud® system to protect electronic components from voltage spikes, polarity reversal and water infiltration. Installation accessories (draining and waterproof outercase) are provided.
Lighting data
Source type
single chip power LED
|
CCT
2700K
|
CRI
> 90
|
MacAdam (SDCM)
2
|
Source lumen output (lm)
236
|
Luminaire lumen output (lm)
71
|
Light emission
Triple grazing
|
Beam angle
30° x 3
|
Photobiological risk
RG0
|
ULR
81.00%
|
BUG Rating
B0 U1 G0
|
CIE Flux Code
0 0 0 0 100
|
LED lifetime
L80 B10 50.000h
|
Efficiency class
This product contains a light source of energy efficiency class (EU2019/2015): F
|
Mechanical data
Height (mm)
105
|
Weight (g)
625
|
IP Rating
IP66 / IP68 10m
|
IK rating
IK10
|
Shape
Round
|
Finishing colour
Steel / Steel
|
Frame material
Stainless steel 316L
|
Body material
Stainless steel 316L
|
External screws material
Stainless steel 316L (A4)
|
Class ISO 9223
CX
|
Optic type
Optical silicone
|
Optical optional
None
|
Maximal working temperature
+50° C
|
Minimal working temperature
-20° C
|
Maximal static load (kN)
5
|
Walk-over
Yes
|
Driver-over
No
|
Maximal surface temperature
+50° C
|
Areas EN 60598-2-13
A1 / A2
|
Electrical data
Nominal power (W)
3
|
Power supply (input power type)
Costant voltage - 24V
|
Ballast
Remote
|
Insulation class
III
|
Dimmable
Yes
|
Power cable type
H05RN - F 2x0,75 mm²
|
Power cable length
15 m (check voltage drop) 15 m (verify voltage drop)
|
Electrical connection
Parallel connection
|
Idroskud® protection
Yes
|
Inverse polarity protection
Yes
|
Voltage spikes protection
Yes
|
Marks
Photometry
Technical drawing
Documentation
Planning
PLEASE NOTE: These professional resources are for registered users only.