Technical description
Linear inground luminaire, drive-over, suitable for outdoor environments (IP66/IP67), with operating temperature range: -20°C / +50°C. The body is made of PMMA, transparent and opal on the upper side; the endcaps are made of 316L stainless steel. The light source is LED SMD3014, powered at 24V with built-in driver. The luminous flux makes it ideal for marking pedestrian and driveway paths, or creating light cuts on floors, walls and ceilings. Color rendering index CRI > 80. Lineo is equipped with IdroSkud® system to protect electronic components from voltage spikes, polarity reversal and water infiltration. Installation accessories are provided (floor and plasterboard outercase; cable extensions up to 15 m).
Lighting data
Source type
SMD chip 3014
|
CCT
4000K
|
CRI
> 80
|
MacAdam (SDCM)
3
|
Source lumen output (lm)
2154
|
Luminaire lumen output (lm)
517
|
Light emission
Diffused
|
Beam angle
120°
|
Photobiological risk
RG0
|
ULR
100.00%
|
BUG Rating
B0 U1 G0
|
CIE Flux Code
0 0 0 0 100
|
LED lifetime
L80 B10 50.000h
|
Efficiency class
This product contains a light source of energy efficiency class (EU2019/2015): F
|
Mechanical data
Width (mm)
27
|
Length (mm)
1510
|
Height (mm)
49
|
Weight (g)
1470
|
IP Rating
IP66 / IP67
|
IK rating
IK10
|
Finishing colour
Opal white
|
Frame material
Stainless steel 316L
|
Body material
Trasparent PMMA
|
External screws material
Stainless steel 316L (A4)
|
Diffuser material
Opal PMMA
|
Class ISO 9223
CX
|
Optical optional
None
|
Maximal working temperature
+50° C
|
Minimal working temperature
-20° C
|
Maximal static load (kN)
20
|
Walk-over
Yes
|
Driver-over
Yes
|
Maximal surface temperature
+50° C
|
Areas EN 60598-2-13
A1 / A2 / A3 / A4
|
Electrical data
Nominal power (W)
18
|
Power supply (input power type)
Costant voltage - 24V
|
Ballast
Remote
|
Insulation class
III
|
Dimmable
Yes
|
Connector type
M12 - 5 poles IP67
|
Power cable length
0,4 m
|
Electrical connection
Parallel connection
|
Idroskud® protection
Yes
|
Inverse polarity protection
Yes
|
Voltage spikes protection
Yes
|
Marks
Photometry
Technical drawing
Documentation